Would some autodetecting on the ports be better in a later release of WSPR? Like HRD etc. Handshake - Hardware (yes I know some others have said no hardware handshake but it only works on mine like this) 1240-1300 MHz is featured in the TS-2000X model. Hi OMs, Ive been the last two days puzzled here around a connection problem with my remote TS-2000.

Kenwood TS-2000 receiver crackling noise problem. No high-priced level converters are required. On VHF/UHF you get: 142-152 and 420-450 MHz. Interface between the TNC and a PC or laptop is accomplished via a DB-9 serial port on the back of the radio. Wide band Main HF reception includes: 30 kHz-60 MHz. Serial rate - 9600 (but must be the same as what you set with menu 56 on the rig!!!) The Kenwood TS-2000 is an all band HF/VHF/UHF transceiver with exceptional features and versatility.

Maybe some rewiring if you know what you are doing or speak to the manufacturer of the interface.ĬAT Port - COM4 (or whatever you have connected your serial cable from the rig to the PC and is on the list in device manager) the CAT port will turn the rig to TX but no audio is getting into the ACC2 connector because the relay isn't energised. You may find that the interface box also only switches in the audio to your rig when the relay is energised.
#Kenwood ts 2000 serial number b6410082 software#
In the latest version, however, I am not able to get the software to connect to the radio whatsoever. You may at this point be thinking, "Why don't I use the same CAT port for the PTT?" (option in PTT method above). Good afternoon, In previous versions, I had no issue connecting WSJT-X to the cat control via serial port on my kenwood TS-2000. PTT port - COM3 (or whatever you have connected your interface box to and is on the list in device manager) Power - set to your power output on your radio, e.g. To set up with the TS2000 you will need the following settings:Īudio in - set to the Microphone port (or wherever you plugged it in to)Īudio out - set to the Speakers port (or wherever you plugged it in to)
#Kenwood ts 2000 serial number b6410082 install#
When you install the two adapters you will see in Device Manager under Ports (COM and LPT) the two Prolific devices, on mine they are COM3 and COM4. With a new PC you will need two USB to serial adapters if you plan to use RTS on one port for PTT switching and the CAT control on the other.

Note this is for use with a serial switching interface (a box with a relay that switches the PTT from your serial port into ACC2 socket on the back of the rig).
#Kenwood ts 2000 serial number b6410082 windows 8.1#
I see many of us are struggling with the CAT settings having upgraded PCs to Windows 8.1 and similar situations.